Dimension Three (D3) CPU Alarm Troubleshooting

Dimension Three (D3) CPU Alarm Troubleshooting

There's a few possible causes of CPU failover in the D3.  There could be an issue with one of the CPU fans, one of the CPU flash drives, one of the CPU modules itself, or the console motherboard.  In addition, a front panel module, for example, could create a glitch that causes a failover.

The following troubleshooting procedures can be helpful in tracing the issue down

  1. Check the CPU fans with power off to make sure they turn freely, and again with power on to make sure they appear to be turning smoothly, with no apparent bearing noise
  2. It's possible to swap flash drives and CPUs, but a couple details must be kept in mind
    1. you can swap the flash drives between the two CPUs to see if that has an effect
    2. you can power down a CPU (by unplugging the power cable to one of the CPUs) to see if the combination of CPU, flash, and RAM has an effect
    3. since there is apparently a rather long delay before a failover this type of swap may not be practical to monitor
    • Related Articles

    • Wheatstone Dimension Three Audio Console Manual

      Dimension Three Manual Download here
    • Dimension Three (D3) vs. Dimension Three Touch (D3T)

      There are two versions of the Dimension Three: Dimenstion 3 (D3) Dimension 3 Touch (D3T) As the name implies, the D3T has a touchscreen. Also, the D3T uses a different operating system. Therefore they have different backend apps and setup programs. ...
    • How To Replace A LXE CPU (Jetway)

      Disconnect the cables and move the LXE console blade from the rack and remove the lid. There are 12 screws that hold the lid in place; six on top and three on each side. Unplug the DC cable and battery backup from the Jetway assembly. Remove the ...
    • Dimension Three Touch (D3T) Setup GUI Common Issues

      Only one connection from the GUI to console is allowed at a time. It's best to install this software on only one machine so you don't have two GUIs fighting over the same socket. If you see in the visibilities list ??idx: (number) instead of the name ...
    • Wheatstone D-12/D-16/D-32 Television Console Manual

      D-12/D-16/D-32 Technical Guide Download here D-16 Admin Manual Download here D-16 Manual Download here D-32 Manual Download here